Performance
|
MOTOR MODEL |
DX65BT-C6 |
DX65BT-C8 |
DX65BT-C10 |
DX65BT-C12 |
|
|
Peak Force |
N |
1848 |
2462 |
3078 |
3694 |
|
Continuous Force1 |
N |
462 |
616 |
770 |
924 |
|
Continuous Force AC2 |
N |
646.8 |
862.4 |
1078.0 |
1293.6 |
|
Continuous Force WC3 |
N |
924 |
1232 |
1540 |
1848 |
|
Peak Power |
W |
3436.6 |
4582 |
5727.6 |
6873 |
|
Continuous Power1 |
W |
214.8 |
286.4 |
358.0 |
429.6 |
|
Continuous Power AC2 |
W |
300.72 |
561.3 |
701.6 |
842.0 |
|
Continuous Power WC3 |
W |
859.2 |
1145.6 |
1432.0 |
1718.4 |
Electrical
|
MOTOR MODEL |
DX65BT-C6 |
DX65BT-C8 |
DX65BT-C10 |
DX65BT-C12 |
|
|
WIRING TYPE UNITS |
T |
T |
T |
T |
|
|
Peak Current |
A pk |
51.2 |
51.2 |
51.2 |
51.2 |
|
Continuous Current1 |
A pk |
12.8 |
12.8 |
12.8 |
12.8 |
|
Continuous Current AC2 |
A pk |
17.9 |
17.9 |
17.9 |
17.9 |
|
Continuous Current WC3 |
A pk |
25.6 |
25.6 |
25.6 |
25.6 |
|
Force Constant |
N/Apk |
36.1 |
48.1 |
60.2 |
72.2 |
|
Back EMF |
V/ms-1 |
41.7 |
55.5 |
69.4 |
83.3 |
|
Resistance 25°C |
ohms |
1.4 |
1.8 |
2.3 |
2.7 |
|
Inductance |
mH |
1.9 |
2.5 |
3.1 |
3.8 |
|
Motor Constant |
N/√W |
31.5 |
36.4 |
40.7 |
44.6 |
|
Max. Terminal Voltage |
VDC |
600 |
600 |
600 |
600 |
Wiring Type: T-Triple Connection
Thermal
|
MOTOR MODEL |
DX65BT-C6 |
DX65BT-C8 |
DX65BT-C10 |
DX65BT-C12 |
|
|
Thermal Resistance 1 |
°C / W |
0.5 |
0.3 |
0.3 |
0.2 |
|
Thermal Resistance AC2 |
°C / W |
0.2 |
0.1 |
0.1 |
0.1 |
|
Thermal Resistance WC3 |
°C / W |
0.1 |
0.07 |
0.07 |
0.05 |
|
Max Winding Temperature |
°C |
120 |
120 |
120 |
120 |
Mechanical
|
MOTOR MODEL |
DX65BT-C6 |
DX65BT-C8 |
DX65BT-C10 |
DX65BT-C12 |
|
|
Coil Weight |
kg |
2.52 |
3.39 |
4.26 |
5.04 |
|
Coil Length |
mm |
361 |
481 |
601 |
721 |
|
Attractive Force |
N |
0 |
0 |
0 |
0 |
|
Electrical Cycle Length |
mm |
60 |
60 |
60 |
60 |
Additional Notes:
· Standard cable length 2 meters.
· 1 Motor coil is thermally insulated from mounting bracket. Ambient temperature. . Coil @ 125°C.
· 2 Motor coil is thermally insulated from mounting bracket. Air cooled @ 20psi
· 3 Motor coil is thermally insulated from mounting bracket. Water cooled @ 20°C
Note: specifications are subject to change without prior notice
Drawings
DX65BT Standard Magnet Track
|
SIZE |
TRACK LENGTH TL (mm) |
WEIGHT (kg) |
MOUNT HOLE A (ea) |
MOUNT HOLE B (ea) |
|
TL 180 |
179.5 |
4.50 |
3 |
3 |
|
TL 240 |
239.5 |
6.00 |
4 |
4 |
|
TL 300 |
299.5 |
7.50 |
5 |
5 |
|
TL 360 |
359.5 |
9.00 |
6 |
6 |
|
TL 600 |
599.5 |
15.00 |
10 |
10 |
|
TL 900* |
899.5 |
22.50 |
15 |
15 |
*EX-STOCK LENGTH
TRACK WEIGHT = 1.5kg PER 60mm.
DX65BT Motor Coil
|
SIZE |
COIL LENGTH CL (mm) |
WEIGHT (kg) |
MOUNT HOLE D (ea) |
|
C6 |
361.0 |
2.52 |
12 |
|
C8 |
481.0 |
3.39 |
16 |
|
C10 |
601.0 |
4.26 |
20 |
|
C12 |
721.0 |
5.04 |
24 |
For COOLING OPTIONS, please ask for detail drawing.
Note: specifications are subject to change without prior notice
Part Numbering System
Coil Assembly
DX50B – C4 – P – TM – 2.0 – A – FC
|
|
|
|
|
|
|
Remarks:
· TM – On/Off switch
· TC – With a simple temperature controller (e.g. Omron), user can read the temperature all the time on a display. User can also set a temperature in the controller to trigger an output
Magnet Track
DX50B – TL300 – K2
|
|
|
Remarks:
· Track length in incremental of 60mm
Note: specifications are subject to change without prior notice