Operator

Voice Coil Modules

CVC - Circular Voice Coil
Dimensions Diagram dividerdivider
Dimensions
Dimensions(mm) CVC 20-10 CVC 30-15 CVC 40-20 CVC 40-HF-6.5 CVC 60-25
A 20.0 30.0 40.0 40.0 60.0
B 16.6 25.2 34.8 34.8 50.6
C 19.0 24.5 32.5 40.5 43.5
D 31.0 39.0 49.8 49.3 66.1
E 10.0 16.0 20.0 20.0 30.0
F 10.0 12.6 20.0 20.0 30.0
X M3 M3 M4 M4 M5
Y M3 M3 M4 M4 M5
Part numbering system dividerdivider
Stroke (mm) 10.0 15.0 20.0 6.5 25.0
Force Constant
(at mid stroke)
2.2 7.5 15.7 26.8 21.1
Back EMF Constant
(at mid stroke), V/m/s
2.2 7.5 15.7 26.8 21.1
Peak Force (N) 5.0 17.1 50.2 104.3 82.5
Continuous Force (N) 2.2
7.5
22.0
45.5 35.9
Continuous Current (A) 1.0 1.0 1.4 1.7 1.7
Peak Current (A) 2.3 2.3 3.2 3.9 3.9
Coil Resistance
(coil at 25°C) (Ω)
3.2 9.9 16.7 11.9 9.0
Coil Resistance
(coil at 100 °C) (Ω)
4.1 12.9 21.6 15.4 11.7
Coil Inductance (mH) 0.6 3.2 12.5 8.0 17.5
Power Loss (at continuous
force, 100 °C) (W)
4.1 12.9 42.4 44.5 33.8
Maximum Allowable
Coil Temperature (C)
155.0 155.0 155.0 155.0 155.0
Recommended Bus
Voltage (V)
24.0 24.0 48.0 60.0 48.0
Coil Clearance (mm) 0.5 0.5 0.5 0.5 0.7
Coil Assembly
Mass (gram)
9.0 24.0 63.0 70.0 204.0
Magnet Assembly
Mass(gram)
30.0 92.0 205.0 200.0 660.0
Part numbering system
Part Numbering diagram
Back  |  Print